Combined Environmental Test Chamber Series
Environmental Reliability Testing
Combines temperature, humidity, vibration, and pressure to reproduce complex operating conditions and validate overall reliability.
Combined Environmental Test Chamber Series
Temperature, Humidity, Altitude & Vibration Combined Test Chamber
The temperature/humidity/altitude/vibration combined test chamber meets the corresponding four-factor test requirements; it serves the aviation, aerospace, ordnance, marine and nuclear industries for electronic instruments, complete electronic units, assemblies and components, as well as materials and processes, under simulated temperature, humidity, altitude (≤30,000 m) and vibration conditions and combined-condition tests.
Core Technical Parameters
Technical Parameters
Temperature Range
-70 °C to +150 °C
Humidity Range
20 %R.H to 98 %R.H
Pressure Range
Ambient to 0.5 kPa
Sine & Random Excitation Force
100 kN
Frequency Range
5 Hz to 2500 Hz
Temperature Change Rate
>10 °C/min (-55 °C to +85 °C, ambient pressure, 150 kg aluminium)
Optional Configurations
Vibration Shaker
Different manufacturers and models selectable
Custom Port Holes
Diameter and quantity per cable requirements
Custom Sample Rack
Designed to the sample and fixture
Additional Shelves
Configured to sample quantity
Product Specifications
PRODUCT PARAMETER
| Model | KMVH | |
|---|---|---|
| Inner Dimensions (mm) | W | 1200 |
| H | 1000 | |
| D | 1200 | |
| Inner Volume | 1200 L | |
| Temperature Range | -70 °C to +150 °C | |
| Humidity Range | 20 %R.H to 98 %R.H | |
| Humidity Deviation | ±5.0 %R.H at ≤75 %R.H; ±3.0 %R.H at >75 %R.H | |
| Pressure Range | Ambient to 0.5 kPa | |
| Sine & Random Excitation Force | 100 kN | |
| Frequency Range | 5 Hz to 2500 Hz | |
| Temperature Change Rate | >10 °C/min (-55 °C to +85 °C, ambient pressure, 150 kg aluminium load) | |
| Inner Material | Stainless steel (SUS304) | |
| Outer Material | Cold-rolled steel sheet with electrostatic powder coating | |
| Insulation | High-density polyurethane foam | |
| Structure | Integrated with the refrigeration system — compact and neat; console set separately for convenient operation | |
| Refrigeration System | Semi-hermetic compressor (compressor unit and key components imported), water-cooled | |
| Heater | Nickel-chromium alloy heater | |
| Blower | Centrifugal fan | |
| Viewing Window | 470 mm × 350 mm coated insulating glass | |
| Temperature Sensor | Pt100 platinum resistance | |
| Controller | Programmable touch-screen controller with automatic temperature/humidity programming and RS485 interface | |
| Safety Devices | Over-temperature, compressor over-pressure / circuit / overload, fan overload, oil pressure, water shortage and earth leakage protection | |
| Vibration Shaker | Optional to customer requirements | |
| Standard Accessories | 1 heat-insulating viewing window, 1 cable port (φ50 mm), 2 baffle racks, interior light | |
| Optional Accessories | Custom port holes, custom sample racks, additional shelves | |
| Manufacturing & Inspection Standards | JJF 1101-2019, GB/T 11158-2008, GB/T 10592-2008, GB/T 10589-2008, GB/T 5170.1-2016, GB/T 5170.2-2017, GB/T 2424 | |
| Compliant Standards | GB/T 2423-2012 (Test A cold, B dry heat, Cab damp heat steady state, Db damp heat cyclic, Z/AD temperature/humidity, Cy 85/85), GB/T 2423.10-2008 (Test Fc vibration), GJB 150A.3 dry heat, GJB 150A.4 cold, GJB 150A.9 damp heat | |
Dimensions and appearance can be customized to customer requirements. We reserve the right to modify technical parameters.
Selection Support & Consulting
Selection for four-factor testing depends on how the four stresses are combined and on the sample condition: the temperature/humidity profile, altitude, vibration spectrum (sine/random) and fixture transmission characteristics must be confirmed together, along with on-site power supply, cooling water and vibration-isolation foundation requirements.
Requirement Review
Clarify the temperature/humidity profile, altitude, vibration spectrum, sample weight, fixture type and applicable standards.
Solution Selection
Match chamber volume, excitation force and frequency range, and verify cooling capacity and temperature change rate including sample heat load.
Custom Design
Cable ports, viewing windows, sample racks, vibration isolation and sealing are customized to the sample and shaker interface.
Delivery & Service
Installation and commissioning, chamber-shaker joint debugging, operator training and long-term technical support.