Thermal Shock Chamber Series
Environmental Reliability Testing
Rapidly switches between hot and cold zones to validate structural integrity and stable performance under extreme thermal shock.
Independent hot & cold zones
Separate temperature control and interlocked doors
Fast basket transfer
30 min exposure each, recovery ≤5 min
Safety interlock
Fan and basket drive cut off when the door opens
Custom dimensions
Fully welded liner, size and appearance customizable
The two-zone thermal shock chamber evaluates how materials and composite structures withstand rapid alternation between high and extremely low temperatures, revealing chemical changes or physical damage caused by thermal expansion and contraction within the shortest time. It is suitable for metals, plastics, rubber, electronic components and similar materials, and provides a basis for product improvement and reliability assessment.
Core Technical Parameters
Technical Parameters
Test zone temperature range
A: -40°C ~ +150°C; B: -55°C ~ +150°C; D: -65°C ~ +150°C
High-temperature zone
+60°C ~ +200°C
Low-temperature zone
A: -55°C ~ -10°C; B: -70°C ~ -10°C; D: -80°C ~ -10°C
Pre-heating time
Within 30 min (+60°C ~ +200°C)
Pre-cooling time
Within 70 min (+20°C ~ -55 / -70 / -80°C)
Recovery time
Within 5 min (30 min exposure each)
Basket volume
64 L ~ 500 L
Controller
7-inch color touch screen (KM-5188)
Power supply
AC380V ±10% 50Hz, 3-phase 4-wire + earth
Configuration & Standards
Refrigeration system
Cascade, semi-hermetic compressor, HFC-R404A/HFC-23
Liner & insulation
Fully welded SUS304 liner, PU insulation grade B1
Standard accessories
2 sample shelves, 1 cable port φ100 mm
Protection devices
Over-temperature, compressor over-pressure/over-heat/over-current, fan overload, dry-heat, water shortage
Standards
GB/T 2423.1-2008, GB/T 2423.2-2008, GJB 150.3-2019, GJB 150.4-2019, GJB 150.5-2019
Product Specifications
PRODUCT PARAMETER
| Model | KTS2-64 | KTS2-100 | KTS2-150 | KTS2-200 | KTS2-300 | KTS2-500 | |
|---|---|---|---|---|---|---|---|
| Basket dimensions (mm) | Width W | 500 | 650 | 710 | 970 | 970 | 1000 |
| Height H | 350 | 350 | 400 | 400 | 460 | 500 | |
| Depth D | 370 | 450 | 530 | 550 | 680 | 1000 | |
| Floor area (m²) | Approx. 1.72 | Approx. 2.08 | Approx. 2.3 | Approx. 2.95 | Approx. 3.73 | Approx. 4.1 | |
| Temperature configuration | A / B / D type (three temperature configurations selectable per size) | ||||||
| High-temperature zone | +60°C ~ +200°C | ||||||
| Pre-heating time | +60°C ~ +200°C, within 30 min | ||||||
| Low-temperature zone | A: -55°C ~ -10°C; B: -70°C ~ -10°C; D: -80°C ~ -10°C | ||||||
| Pre-cooling time | A: +20°C ~ -55°C, within 70 min; B: +20°C ~ -70°C; D: +20°C ~ -80°C | ||||||
| Test zone temperature range | A: -40°C ~ +150°C; B: -55°C ~ +150°C; D: -65°C ~ +150°C | ||||||
| Temperature recovery time | 30 min exposure at high and low temperature respectively, recovery within 5 min | ||||||
| Inner chamber material | SUS304 stainless steel plate, fully welded inner liner | ||||||
| Outer cabinet material | High-quality cold-rolled steel plate with electrostatic powder coating | ||||||
| Insulation material | Rigid polyurethane foam insulation, flame-retardant grade B1 | ||||||
| Refrigeration system | Cascade system, semi-hermetic compressor, HFC-R404A/HFC-23 refrigerant | ||||||
| Controller | KOMEG 7-inch color touch screen controller (KM-5188 thermal shock system) | ||||||
| Protection devices | No-fuse breaker, compressor over-pressure / over-heat / over-current protection, over-temperature protection, fan overload protection, fuse, dry-heat protector, water shortage protection | ||||||
| Standard accessories | Sample shelves ×2, cable port (φ100 mm) ×1 | ||||||
| Power supply | AC380V ±10% 50Hz, 3-phase 4-wire + earth | ||||||
| Standards | GB/T 2423.1-2008, GB/T 2423.2-2008, GJB 150.3-2019, GJB 150.4-2019, GJB 150.5-2019 | ||||||
Note: A / B / D temperature configurations are available for each size. Dimensions and parameters above are nominal; actual dimensions and appearance can be customized. We reserve the right to modify technical parameters.
Selection Support & Consulting
Selection support for thermal shock testing: based on sample size and load, temperature configuration and recovery-time requirements, applicable standards and site conditions, we recommend the chamber type, basket size and refrigeration configuration.
Requirements Discussion
Understand test objectives, sample characteristics, operating conditions, and standards to define key requirements and constraints.
Solution Selection
Match suitable product solutions and configurations to the requirements, providing recommendations and a basis for selection.
Custom Design
Provide customized designs for special requirements, including structural optimization, functional extensions, and system integration.
Delivery Service
Professional production and quality control, rapid delivery, and installation, commissioning, training, and long-term technical support.